HomeFreeBSD

ichsmb: fix block read operation

Description

ichsmb: fix block read operation

First of all and unlike I2C, it's not the master that dictates how many
bytes to read in block read operation. It's the device that informs the
master how many bytes it's sending back.

Thus, for ichsmb_bread() the count parameter is purely an output
parameter. The code has been changed to reflect that.
The sanity checking of the response length is now done once it (the
first byte of the response) is received.

While here, handling of ICH_HST_STA_FAILED status bit has been added.
Plus some code style improvements and some new code comments in the
vicinity of the changed code.

(cherry picked from commit cbf7c81b608bb9311e50df9481447dc843083a0e)

Details

Provenance
avgAuthored on Sep 13 2022, 9:26 PM
Parents
rGb5d826b1b6bc: change ipmi watchdog to awlays stop when system is halted
Branches
Unknown
Tags